https://doi.org/10.1051/epjap:2004222
Electrostatic force measurements in positive unipolar wire-to-plane corona discharges in air
BonPhysics B.V., Laan van Heemstede 38, 3297 AJ Puttershoek, The Netherlands
Corresponding author: victor@bonphysics.nl
Received:
12
July
2004
Revised:
21
September
2004
Accepted:
22
October
2004
Published online:
21
December
2004
Measurements of electrostatic force generated in the drift region of a positive unipolar wire-to-plane corona discharge in air are compared with numerical simulations. The generated force does not depend on the ion mobilities, preventing the influence of uncertainty and variation of these parameters. A method is described to simulate the voltage and charge distribution for a wire-to-plane set-up. This method enables the determination of the transition between unipolar and bipolar discharges. In the experimental set-up breakdown electric field of air reduces with increasing discharge current.
PACS: 02.60.Cb – Numerical simulation; solution of equations / 02.70.Bf – Finite-difference method / 52.80.Hc – Glow; corona
© EDP Sciences, 2005