https://doi.org/10.1051/epjap/2009144
Optimizations of ozone generator at low resonance frequency
Center of Plasma Technology, Faculty of Science, Al-azhar University, Nasr
City, Cairo, Egypt
Corresponding author: abdougaramoon@hotmail.com
Received:
20
March
2009
Accepted:
8
June
2009
Published online:
17
September
2009
The effect of the frequency on the different parameters of ozone generation
in the dielectric barrier discharge (DBD) has been investigated. It is found
that at low frequency, ( Hz), an electric resonance can be
obtained in the electric circuit. The onset voltage, at which the ozone
starts to build up, was reduced from 3.25 kV at 50 Hz to 1.57 kV at 325 Hz.
The efficiency has been increased from nearly zero at 50 Hz to 232.94 g/kW h
at 200 Hz under applied voltage of 2.025 kV.
PACS: 51.50.+v – Electrical properties / 52.80.Mg – Arcs; sparks; lightning; atmospheric electricity / 52.80.Pi – High-frequency and RF discharges / 52.90.+z – Other topics in physics of plasmas and electric discharges
© EDP Sciences, 2009